Description
|
|
Model
|
Refrig.
|
Flow Rate
|
Pressure
drop |
Connections
|
Power Supply
|
Dimensions [mm] Weight
|
|||||||||
Nl/min | Nm/h | scfm | bar | Ø IN-OUT | Ph/V/Fr | A | B | C | D | E | F | G | (Kg) | ||
ACT 3
|
R134.a | 350 | 21 | 12 | 0.02 | G1/2″BSP-F | 1/230-240/50 | 345 | 420 | 740 | 158 | 56 | 700 | 770 | 28 |
ACT 5
|
R134.a | 550 | 33 | 19 | 0.03 | G1/2″BSP-F | 1/230-240/50 | 345 | 420 | 740 | 158 | 56 | 700 | 770 | 29 |
ACT 8
|
R134.a | 850 | 51 | 30 | 0.08 | G1/2″BSP-F | 1/230-240/50 | 345 | 420 | 740 | 158 | 56 | 700 | 770 | 31 |
ACT 12
|
R134.a | 1.200 | 72 | 42 | 0.11 | G1/2″BSP-F | 1/230-240/50 | 345 | 420 | 740 | 158 | 56 | 700 | 770 | 34 |
ACT 18
|
R134.a | 1.800 | 108 | 64 | 0.13 | G1″BSP-F | 1/230-240/50 | 345 | 420 | 740 | 130 | 56 | 657 | 775 | 36 |
ACT 23
|
R134.a | 2.300 | 138 | 81 | 0.17 | G1″BSP-F | 1/230-240/50 | 345 | 420 | 740 | 130 | 56 | 657 | 775 | 37 |
ACT 30
|
R404A | 3.100 | 186 | 109 | 0.15 | G1.1/4″BSP-F | 1/230-240/50 | 485 | 455 | 825 | 130 | 69 | 745 | 865 | 46 |
ACT 40
|
R404A | 4.000 | 240 | 141 | 0.20 | G1.1/4″BSP-F | 1/230-240/50 | 485 | 455 | 825 | 130 | 69 | 745 | 865 | 50 |
ACT 55
|
R404A | 5.500 | 330 | 194 | 0.15 | G1.1/2″BSP-F | 1/230-240/50 | 555 | 580 | 885 | 135 | 85 | 800 | 935 | 55 |
ACT 60
|
R404A | 6.200 | 372 | 219 | 0.18 | G1.1/2″BSP-F | 1/230-240/50 | 555 | 580 | 885 | 135 | 85 | 800 | 935 | 63 |
ACT 80
|
R404A | 8.100 | 486 | 286 | 0.09 | G2″BSP-F | 1/230-240/50 | 555 | 625 | 975 | 240 | 100 | 865 | 1.030 | 92 |
ACT 100
|
R404A | 10.500 | 630 | 371 | 0.13 | G2″BSP-F | 1/230-240/50 | 555 | 625 | 975 | 240 | 100 | 865 | 1.030 | 94 |
ACT 120
|
R404A | 12.500 | 750 | 441 | 0.07 | G2.1/2″BSP-F | 1/230-240/50 | 665 | 725 | 1.105 | 375 | 190 | 940 | 1.155 | 141 |
ACT 140
|
R404A | 14.500 | 870 | 512 | 0.13 | G2.1/2″BSP-F | 1/230-240/50 | 665 | 725 | 1.105 | 375 | 190 | 940 | 1.155 | 150 |
ACT 160
|
R404A | 16.000 | 960 | 565 | 0.15 | G2.1/2″BSP-F | 1/230-240/50 | 665 | 725 | 1.105 | 375 | 190 | 940 | 1.155 | 161 |
ACT 80 3~
|
R404A | 8.100 | 486 | 286 | 0.08 | G2″BSP-F | 3/400-415/50 | 555 | 625 | 975 | 245 | 100 | 865 | 1.035 | 100 |
ACT 100 3~
|
R404A | 10.500 | 630 | 371 | 0.13 | G2″BSP-F | 3/400-415/50 | 555 | 625 | 975 | 245 | 100 | 865 | 1.035 | 102 |
ACT 120 3~
|
R404A | 12.500 | 750 | 441 | 0.09 | G2.1/2″BSP-F | 3/400-415/50 | 665 | 725 | 1.105 | 375 | 190 | 940 | 1.155 | 149 |
ACT 140 3~
|
R404A | 14.500 | 870 | 512 | 0.14 | G2.1/2″BSP-F | 3/400-415/50 | 665 | 725 | 1.105 | 375 | 190 | 940 | 1.155 | 158 |
ACT 160 3~
|
R404A | 16.000 | 960 | 565 | 0.15 | G2.1/2″BSP-F | 3/400-415/50 | 665 | 725 | 1.105 | 375 | 190 | 940 | 1.155 | 169 |
ACT 180
|
R404A | 18.000 | 1.080 | 636 | 0.17 | DN80-PN 16 | 3/400-415/50 | 785 | 950 | 1.410 | 500 | 220 | 1.155 | 1.490 | 232 |
ACT 210
|
R404A | 21.000 | 1.260 | 742 | 0.21 | DN80-PN 16 | 3/400-415/50 | 785 | 950 | 1.410 | 500 | 220 | 1.155 | 1.490 | 242 |
ACT 250
|
R404A | 25.000 | 1.500 | 883 | 0.13 | DN80-PN 16 | 3/400-415/50 | 785 | 950 | 1.410 | 500 | 220 | 1.155 | 1.490 | 267 |
ACT 300
|
R404A | 30.000 | 1.800 | 1.060 | 0.19 | DN80-PN 16 | 3/400-415/50 | 785 | 950 | 1.410 | 500 | 220 | 1.155 | 1.490 | 227 |
ACT 360
|
R404A | 36.800 | 2.208 | 1.300 | 0.26 | DN80-PN 16 | 3/400-415/50 | 785 | 1.040 | 1.410 | 500 | 265 | 1.155 | 1.485 | 302 |
ACT 400
|
R404A | 40.000 | 2.400 | 1.413 | 0.21 | DN100-PN 16 | 3/400-415/50 | 1.005 | 1.535 | 1.785 | N.A. | N.A. | N.A. | 1.840 | 530 |
ACT 500
|
R404A | 50.000 | 3.000 | 1.766 | 0.14 | DN100-PN 16 | 3/400-415/50 | 1.005 | 1.535 | 1.785 | N.A. | N.A. | N.A. | 1.840 | 580 |
ACT 600
|
R404A | 60.000 | 3.600 | 2.119 | 0.20 | DN100-PN 16 | 3/400-415/50 | 1.005 | 1.535 | 1.785 | N.A. | N.A. | N.A. | 1.955 | 590 |
ACT 720
|
R404A | 73.600 | 4.416 | 2.600 | 0.26 | DN125-PN 16 | 3/400-415/50 | 1.005 | 1.535 | 1.785 | N.A. | N.A. | N.A. | 1.840 | 700 |
ACT 900
|
R404A | 90.000 | 5.400 | 3.178 | 0.20 | DN150-PN 16 | 3/400-415/50 | 1.005 | 1.855 | 1.785 | N.A. | N.A. | N.A. | 1.840 | 840 |
ACT 1100
|
R404A | 110.000 | 6.624 | 3.900 | 0.26 | DN150-PN 16 | 3/400-415/50 | 1.005 | 1.900 | 1.785 | N.A. | N.A. | N.A. | 1.840 | 1.010 |
ACT 1200
|
R404A | 120.000 | 7.200 | 4.238 | 0.20 | DN150-PN 16 | 3/400-415/50 | 1.005 | 2.065 | 1.785 | N.A. | N.A. | N.A. | 1.840 | 1.020 |
ACT 1500
|
R404A | 147.200 | 8.832 | 5.200 | 0.26 | DN200-PN 16 | 3/400-415/50 | 1.005 | 2.735 | 1.785 | N.A. | N.A. | N.A. | 1.840 | 1.350 |
CORRECTION FACTOR FOR OPERATING PRESSURE CHANGES: | ||||||||
Inlet air pressure barg | 4 | 5 | 6 | 7 | 8 | 10 | 12 | 14 |
Factor | 0.77 | 0.86 | 0.93 | 1.00 | 1.05 | 1.14 | 1.21 | 1.27 |
CORRECTION FACTOR FOR AMBIENT TEMPERATURE CHANGES (AIR-COOLED): | |||||
Ambient temperature °C | 25 | 30 | 35 | 40 | 45 |
Factor | 1.00 | 0.99 | 0.97 | 0.93 | 0.88 |
CORRECTION FACTOR FOR INLET AIR TEMPERATURE CHANGES: | ||||||||||
Air Temperature °C | 25 | 30 | 35 | 40 | 45 | 50 | 55 | 60 | 65 | 70 |
Factor | 1.27 | 1.12 | 1.00 | 0.88 | 0.78 | 0.70 | 0.62 | 0.55 | 0.49 | 0.43 |
CORRECTION FACTOR FOR DEWPOINT CHANGES: | ||||
DewPoint °C | 3 | 5 | 7 | 10 |
Factor | 1.00 | 1.09 | 1.19 | 1.37 |